VAN BUILD TOOLKIT

Build the electrical system before buying the wrong bits.

Work out what you use, size the battery, plan solar charging and finish with the cable and protection for each circuit. The tools stay linked, so changing your daily energy use feeds the battery and solar estimates automatically.

Starting from scratch? Work through the tools in order. Already know what you need? Jump straight to any calculator. Example values are prefilled so you can see the tools working; replace them with your own.

01 • ENERGY BUDGET

What will all this stuff use?

Add devices, wattage and daily runtime. AC loads include inverter losses.

Used to convert daily watt-hours into approximate amp-hours.
AC appliances draw extra battery energy because an inverter is not 100% efficient.
DeviceWattsQtyHours/daySupplyWh/day
Daily energy
0 Wh
Battery draw
0 Ah/day
Average load
0 W
30-day energy
0 kWh
Daily Wh feeds the battery and solar sections automatically. Wh/day is the total energy used over a day; Ah/day expresses that energy at the selected system voltage.
Next step: turn that daily energy use into a battery target.Next: size your battery
02 • BATTERY SIZING

Voltage and chemistry are separate things.

Pick the system voltage independently from chemistry, then optionally model the physical batteries in series and parallel.

Capacity required from your loads

Wh/day, fed from the appliance calculator.
How long the bank should support the planned loads without useful charging.
Extra capacity above the calculated requirement for uncertainty and changing use.
Recommended capacity
—
Nominal energy
—
Usable target
—
Rounded target
—
Next step: turn the capacity target into a physical battery layout.Next: build the battery bank
03 • BATTERY BANK

Build the physical battery bank.

Model the batteries in series and parallel to see the resulting bank voltage, capacity, energy and physical battery count.

Ah of each physical battery.
Series adds voltage; the Ah capacity of one string stays the same.
Parallel adds Ah capacity while keeping the string voltage the same.
Bank voltage
—
Bank capacity
—
Bank energy
—
Physical batteries
—
Next step: work out how solar can recharge the bank.Next: plan solar charging
04 • PV ARRAY + MPPT

Use the numbers on the panel label.

Enter W, Voc, Vmp, Isc and Imp, build the series/parallel array, cold-correct Voc, then compare it with a controller database sourced from official manufacturer specifications.

W
V. Rises as the panel gets colder.
V. Working voltage near maximum power.
A. Used when checking controller and protection limits.
A. Working current at maximum power.
% / °C. Often printed on the datasheet rather than the label.
°C. Used with the temperature coefficient to estimate worst-case cold Voc.
Array power
—
Array Voc / cold Voc
—
Array Vmp
—
Array Isc / Imp
—

Controller matcher

Official data snapshot: Sep 2026
Manufacturer dataset: Victron SmartSolar, Renogy Rover, EPEVER XTRA/Tracer AN, Morningstar TriStar/GenStar, Votronic MPP Duo Digital, OutBack FLEXmax and MidNite Classic families. Data is a planning snapshot from official product pages/datasheets; always re-check the current manual before purchase or wiring.

MPPT reference list

Use this table to compare the published limits before using the interactive matcher. PV voltage minimums are the manufacturer start/operating rule where captured; “See manual” means the current source data does not give a single comparable figure. PV watts are the published recommended or nominal array limits for each battery voltage, not a guarantee of production.

Manufacturer / modelNominal battery VPV voltage min / maxMax PV IscMax charge APublished PV watts by battery V
Next step: estimate what the array may actually produce. Learn more about series and parallel wiring.Next: estimate solar yield
05 • SOLAR YIELD

What might the roof make?

Broad planning estimate by latitude, month, roof angle and climate. Useful for comparing scenarios, not pretending next Tuesday's cloud knows our spreadsheet.

Planning allowance for real-world system losses rather than panel-nameplate output.
Wh/day. This is fed automatically from the Power Usage tool.
Estimated daily solar
—
Equivalent peak sun
—
Demand covered
—
Array for 100%
—
This is not a location-specific irradiance database yet. Local cloud history, shading, snow, dirt and horizon conditions can move real production dramatically. A future version can be connected to a proper solar-resource dataset.
Next step: size the cable and protection for an individual circuit.Next: size a circuit
06 • DC CABLING

Cable, voltage drop & fuse.

Sizes copper cable from voltage, load and one-way run length. The full positive + negative circuit length is used internally.

Amps
Metres from source to load.
Lower allowed drop usually means a larger cable and less energy lost as heat.
Planning headroom used when suggesting a fuse; cable and equipment limits still take priority.
Recommended cable
—
Approx. AWG
—
Actual drop
—
Suggested fuse
—
Planning aid only. Final cable ampacity and fuse selection depend on insulation, temperature, bundling, installation method, equipment manuals and local standards.
Finished the toolkit? Read the 12V planning guide for the bigger system picture.Read the 12V planning guide